Filter Results By:

Products

Applications

Manufacturers

Dew Point

is the temperature at which evaporation and condensation occur at the same rate.


Showing results: 181 - 195 of 213 items found.

  • Compact USB Data Logger with Display

    DW-USB-LCD - Dwyer Instruments Inc.

    The Portable Series DW-USB-LCD USB Data Loggers displays and records temperature, humidity and dew point. The easy-to-read LCD display shows the current temperature or humidity along with the minimum and maximum reading since last reset. For applications that require more accuracy, a high accuracy temperature and humidity model is available. Thermocouple models can accept any J, K, or T type thermocouple with a mini-plug connector.

  • Indoor Air Quality, Carbon Dioxide (CO2)

    Extech CO240 - Extech Instruments Corporation

    The CO240 measures Carbon Dioxide (CO2), Air Temperature and Humidity, as well as Dew Point and Wet Bulb calculations. The user settable high alarm with audible beeper is perfect for conducting a quick check of CO2 level to help adjust the environmental conditions in an enclosed area, such as a greenhouse or nursery, to insure optimal plant grown. Complete with six AAA batteries, USB cable, PC software and soft case.

  • Portable Sulphuric Acid Dewpoint Temperature Monitor

    Walsn Enterprises Ltd.

    The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.

  • Web Sensor with PoE

    T3610 - COMET SYSTEM, s.r.o.

    PoE Web Sensor with built-in relative humidity and temperature sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Power over Ethernet feature according IEEE 802.3af is supported. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • 11-in-1 Environmental Meter

    Extech EN100 - Extech Instruments Corporation

    The EN100 is a Compact Hygro-Thermo-Anemometer with Light Sensor. 11-in-1 Environmental Meter for indoor and outdoor conditions. Built in light sensor measures light level. Auto-rotating display depending on selected function. Also measures Air Velocity, Air Flow, Temperature, Humidity, Wet Bulb, Dew Point, Heat Index, Wind Chill, Barometric Pressure and Altitude. Complete with built-in multiparameter sensors, wrist strap, and CR2032 battery.

  • Multi-Sense Humidity Probe

    HP125 Series - Edgetech Instruments

    The HP125 Multi-Sense Humidity Probe is a cost effective, easy to use solution to many industrial and laboratory measurement and control applications. The HP125 probe exploits the latest advancements in polymer humidity sensing technology and compact electronic circuitry. It is designed to continuously measure up to 4 measurement parameters using a single intelligent sensor tip including RH%, calculated Dew Point, Temperature and either Absolute Pressure or Barometric Pressure!

  • Web Sensor with PoE

    T7610 - COMET SYSTEM, s.r.o.

    PoE Web Sensor with built-in temperature, relative humidity and atmospheric pressure sensors.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Power over Ethernet feature according IEEE 802.3af is supported. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • Humidity and Temperature USB Datalogger - Reccords up to 16,000 Readings for Each Parameter

    Extech RHT10 - Extech Instruments Corporation

    The RHT10 datalogs Humidity and Temperature readings (up to 16,000 each) with user programmable sample rates from 2 seconds up to 24 hours for days, weeks and months. USB interface for easy setup and download. Dew Point indication via the included Windows software. User-programmable High/Low alarm thresholds for RH and temperature. Complete with 3.6-Volt Lithium battery, protective USB cap, mounting bracket, and Windows compatible software for analysis.

  • Precision Hygro-Thermometer

    Extech RH490 - Extech Instruments Corporation

    Anyone whose job relies on calculating humidity levels will appreciate the Extech Hygro-Psychrometer. In addition to measuring relative humidity in 30 seconds, this handheld instrument captures dew point, wet bulb, temperature and water vapor levels (Grams per Kilogram and Grains per Pound). This utility tool will store maximum and minimum readings until the memory is cleared and includes a data-hold button for rapidly fluctuating measurements. Complete with carrying case and 9V battery.

  • Precision Psychrometer - Highest 2% RH Accuracy With Fast 30 Seconds Response Time

    Extech RH390 - Extech Instruments Corporation

    Measure humidity and temperature simultaneously with the RH390 Precision Psychrometer from Extech. A dual-illuminated readout can be alternated to display wet bulb and humidity, or dew point and humidity, or temperature and humidity. This handheld device registers temperatures from -22 degrees to 199 degrees F (-30 degrees to 100 degrees C) and measures the full spectrum of relative humidity with ±2% accuracy between 20 and 90% RH. Complete with carrying case and 9V battery.

  • Psychrometers

    General Tools & Instruments

    All psychrometers derive an environment's wet-bulb and dew point temperatures from a precise measurement of relative humidity. The original psychrometer had two thermometers mounted together with a handle attached on a chain. One thermometer was ordinary. The other had a cloth wick over its bulb and was called a wet-bulb. New, digital versionslike General's EP870X family improve on this basic design, offer HVAC technicians a better tool for recharging the refrigerant of a residential or commercial A/C system.

  • Thermometer Hygrometer Barometer

    H7531-4 - COMET SYSTEM, s.r.o.

    Sensor H7531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • Thermometer Hygrometer

    H3531-2 - COMET SYSTEM, s.r.o.

    Sensor H3531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • Thermometer Hygrometer

    H3531-4 - COMET SYSTEM, s.r.o.

    Sensor H3531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • Thermometer Hygrometer Barometer

    H7531-2 - COMET SYSTEM, s.r.o.

    Sensor H7531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

Get Help